AEI Cables - Products - ISO9001 - BASEC - LPCB - Lloyds

logo

Login Help

Please enter your email address that you registered with. We will email you your password so you can sign in.

Your email and password are case sensitive.

* denotes a mandatory field.

Member Login

Update my password

Lost Login

Not a member yet?

Update my profile

Our products

Quality and safety are the hallmarks of our diverse range of products, which are designed and manufactured to the very highest standards such as ISO 9001 and approved by the leading approvals organisations nationally and internationally including BASEC, LPCB and Lloyds.

Please click on a category below to display

0 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - A - B - C - D - E - F - G - H - I - J - K - L - M - N - O - P - Q - R - S - T - U - V - W - X - Y - Z
 
0Print summary for selected product(s)
Print
Compare two selected products
Compare
0.15/0.25kV BS 6883 - Multi-pair Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened pairs, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 7, 8, 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-pair Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened pairs, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 5, 6, 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-quad Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually screened quads, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 14
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-quad Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened quads, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 13
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-triple Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened triples, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 11, 12, 25,26
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 6883 - Multi-triple Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits.
Construction Stranded tinned copper conductors, elastomer insulated, individually or collectively screened triples, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS6883 Table 9, 10, 22,23
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 7917 - Multi-pair Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened pairs, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 8, 9
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 7917 - Multi-pair Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened pairs, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White and black numbered pairs
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 6, 7
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 7917 - Multi-quad Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually screened quads, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 15
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 7917 - Multi-triple Armoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened triples, layed up, LSZH bedding, GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 12, 13
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.15/0.25kV BS 7917 - Multi-triple Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually or collectively screened triples, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black and red numbered triples
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 10, 11
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request
Min temperature for installation is -15degC
0.15/0.25kV BS7917 - Multi-quad Unarmoured
Datasheet
Approval
Voltage Rating 150/250 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, individually screened quads, layed up, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification White, black, red and blue numbered quads
Sheath Colour Grey, blue others on request
Manufacturing Standard BS7917 Table 14
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.6/1.0kV BS 6883 - Armoured
Datasheet
Approval
3D Model
Voltage Rating 600/1000 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or multicore, LSZH bedding, single core TPBB or multicores GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or 1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS6883 Tables 20, 21, 22, 23, 24
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.6/1.0kV BS 6883 - Unarmoured
Datasheet
Approval
Voltage Rating 600/1000 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single, two, three, four core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or 1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS6883 Tables 18,19
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.6/1.0kV BS 7917 - Armoured
Datasheet
Approval
Voltage Rating 600/1000 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or multicore, LSZH bedding, single core TPBB or multicore GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or
1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS7917 Tables 21, 22, 23, 24, 25
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
0.6/1.0kV BS 7917 - Unarmoured
Datasheet
Approval
Voltage Rating 600/1000 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductors, fire barrier tape, elastomer insulated, single, two, three, four core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification Either white with printed numbers or
1 core Bk
2 core Rd, Bk
3 core Rd, Yw, Be
4 core Rd, Yw, Be, Bk
multicores white numbered
Sheath Colour Black
Manufacturing Standard BS7917 Tables 19, 20
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
1Print summary for selected product(s)
Print
Compare two selected products
Compare
1.9/3.3kV BS 6883 - Armoured
Datasheet
Voltage Rating 1900/3300 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS6883 Tables 30, 31
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
1.9/3.3kV BS 7917 - Armoured
Datasheet
Voltage Rating 1900/3300 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS7917 Tables 31, 32
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
2Print summary for selected product(s)
Print
Compare two selected products
Compare
2182/3/4Y (H03VVF)
 Product Image
Datasheet
3D Model
Voltage Rating 300/300 volts
Description PVC Light Duty Flexible Cords
Construction Plain copper conductor, PVC insulated two, three or four cores twisted together and PVC sheathed
Operating Temperature -15degC to +70degC
Minimum Bending Radius 3x
Core Identification 2 core Be, Bn
3 core Gn/Yw, Be, Bn
4 core Gn/Yw, Bn, Bk, Gy.
Lengths 50/100m
Sheath Colour White or black
Manufacturing Standard BS 6500:2000 Table 26
BS EN 50525-2-11 Table B1
Code of Practice/
Guide to Use
BS 7540
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes Min temperature for installation is +5degC
2192Y (H03VVH2-F)
 Product Image
Datasheet
3D Model
Voltage Rating 300/300 volts
Description PVC Light Duty Flexible Cords (Flat)
Construction Plain copper conductors, PVC insulated, two cores laid flat and PVC sheathed.
Operating Temperature -15degC to +70degC
Minimum Bending Radius 3x
Core Identification Be and Bn
Lengths 50/100m
Sheath Colour White
Manufacturing Standard BS 6500:2000 Table 26
BS EN 50525-2-11 Table B1
Code of Practice/
Guide to Use
BS 7540
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes Min temperature for installation is +5degC
3Print summary for selected product(s)
Print
Compare two selected products
Compare
3.3/3.3kV BS 6883 - Armoured
Datasheet
Voltage Rating 3300/3300 volts
Description Elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductors, elastomer insulated, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS6883 Tables 32, 33
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
3.3/3.3kV BS 7917 - Armoured
Datasheet
Voltage Rating 3300/3300 volts
Description Fire resistant, elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications where fire integrity is essential.
Construction Stranded tinned copper conductor, fire barrier tape, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 4x diameter for <25mm
6x diameter for >25mm
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Black
Manufacturing Standard BS7917 Tables 33, 34
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests IEC 60331
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
3.8/6.6kV BS 6883 - Armoured (Non radial field)
Datasheet
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 12x diameter
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 37, 38
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
3.8/6.6kV BS 6883 - Armoured (Radial field)
Datasheet
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 48, 49
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
3.8/6.6kV BS 6883 - Unarmoured (Radial field)
Datasheet
Voltage Rating 3800/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 46, 47
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
3092/3/4Y (H05V2V2-F)
 Product Image
Datasheet
3D Model
Voltage Rating 300/500 volts
Description PVC Ordinary duty flexible cords (Heat Resisting). Heat resisting flexible cords for use in higher temperatures as a feed for portable tools, immersion heaters etc.
Construction Plain copper conductors, HRPVC insulated 2,3,4 cores twisted together and HRPVC sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 3x for fixed wiring
6x for flexing
Core Identification 2 core Be, Bn
3 core Gn/Yw, Be, Bn
4 core Gn/Yw, Bn, Bk, Gy
Lengths 50/100m
Sheath Colour White
Manufacturing Standard BS6500:2000 Table 29
BSEN50525-2-11 Table B2
Code of Practice/
Guide to Use
BS 7540
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes Where a conductor operates at a temperature exceeding 70C it shall be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
Min temperature for installation is +5degC
3182/3/4/5Y (H05VV-F)
 Product Image
Datasheet
3D Model
Voltage Rating 300/500 volts
Description PVC Ordinary duty flexible cords. General purpose flexible cords for feeds to portable tools and domestic appliances. Can be used indoors or outdoors where extreme temperatures are not expected. See special notes for alternative flexible cords for higher and lower temperature applications.
Construction Plain copper conductors, PVC insulated cores twisted together, PVC sheathed.
Operating Temperature -15degC to +70degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification 2 core Be, Bn
3 core Gn/Yw, Be, Bn
4 core Gn/Yw, Bn, Bk, Gy
5 core Gn/Yw, Be, Bn, Bk, Gy
Lengths 50/100m
Sheath Colour White
Manufacturing Standard BS6500:2000 Table 27
BS EN 50525-2-11 Table B2
Code of Practice/
Guide to Use
BS 7540
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes For higher temperature flex see Heat Resisting.
For low temperature flex see Arctic grade
Min temperature for installation is +5degC
3183A (Arctic Grade)
 Product Image
Datasheet
3D Model
Voltage Rating 300/500 volts
Description PVC Ordinary Duty Flexible Cords (Arctic Grade). These cords retain their flexibility at low temperatures, to -25C, and are therefore suitable for indoor and outdoor use to feed equipment such as temporary traffic lights and portable tools.
Construction Flexible plain copper conductors, low temperature PVC insulation, cores laid up, low temperature PVC sheath.
Operating Temperature -25degC to +70degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification 3 core Gn/Yw, Be, Bn
Lengths 100m
Sheath Colour Blue or yellow
Manufacturing Standard BS6004 Table 6
BS7919:2001 Table 44
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
6Print summary for selected product(s)
Print
Compare two selected products
Compare
6.35/11kV BS 6883 - Armoured (Non radial field)
Datasheet
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 12x diameter
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 41, 42
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
6.35/11kV BS 6883 - Armoured (Radial field)
Datasheet
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 52, 53
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
6.35/11kV BS 6883 - Unarmoured (Radial field)
Datasheet
Voltage Rating 6350/11000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 50, 51
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
6.6/6.6kV BS 6883 - Armoured (Non radial field)
Datasheet
Voltage Rating 6600/6600 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, single core or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 12x diameter
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 39, 40
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
6181XLPE
 Product Image
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description PVC Surface Wiring. These are rated at 90C rather than 70C for 6181Y PVC insulated cables and therefore have a higher current carrying capacity for an equivalent size of cable. For use in light industrial and domestic applications where the risk of mechanical damage is low. They may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction Stranded plain copper conductors, XLPE insulation, PVC sheath
Operating Temperature -15degC to +90degC
Minimum Bending Radius 4x 50sqmm to 185sqmm
6x 240sqmm to 1000sqmm
Core Identification Bn or Be
Sheath Colour Black
Manufacturing Standard BS7889 Table 3
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes Where a conductor operates at a temperature exceeding 70C it shall be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature
. Min temperature for installation is +5gegC
6181Y-H
 Product Image
Datasheet
3D Model
Voltage Rating 300/500 volts
Description PVC Surface Wiring. Often referred to as 'double insulated cable'. For use in light industrial and domestic applications where the risk of mechanical damage is low. They may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction Plain copper conductor, single core, PVC insulated and PVC sheathed
Operating Temperature -15degC to + 70degC
Minimum Bending Radius 3x 1.0sq to 16sq
4x 25sq to 35sq
Core Identification Bn or Be
Lengths 100m 1.0 1.5
50/100m 16 - 35
Special lengths available on request.
Sheath Colour Grey
Manufacturing Standard BS6004 Table 3
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes Min temperature for installation is +5degC
6192/3Y
 Product Image
Datasheet
3D Model
Voltage Rating 300/500 volts
Description PVC Surface Wiring
Construction Plain copper conductors, PVC insulated cores laid flat and PVC sheathed.
Operating Temperature -15degC to +70degC
Minimum Bending Radius 4x
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy.
Sheath Colour Grey
Manufacturing Standard BS6004 Table 3
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes Min temperature for installation is +5degC
6241Y
 Product Image
Datasheet
3D Model
Voltage Rating 300/500 volts
Description PVC Surface Wiring. For use in light industrial and domestic applications where the risk of mechanical damage is low. It may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction Solid plain copper conductors, single core, PVC insulated, core laid flat with a non insulated circuit protective conductor (cpc), PVC sheath.
Operating Temperature -15degC to +70degC
Minimum Bending Radius 3x
Core Identification Bn or Be
Lengths 100m
Sheath Colour Grey
Manufacturing Standard BS6004Table 4
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes Min temperature for installation is +5degC
6242/3B
 Product Image
Datasheet
3D Model
Voltage Rating 300/500 volts
Description Low Smoke Zero Halogen Surface Wiring. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. For use in light industrial and domestic applications where the risk of mechanical damage is low. It may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction Plain copper conductors, XLPE insulation, cores laid flat with a non insulated circuit protective conductor (cpc), LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 3x 1sqmm to 2.5sq 2 core
4x 4sqmm to16sqmm 2 core
4x 1sqmm to 10sqmm 3core
6x 16sq 3 core.
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy.
Lengths 100/500m 1.5 - 6.0
100m 10.0 - 16.0
100m 6243B 1.5
Sheath Colour White
Manufacturing Standard BS7211 Table 5
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265 (IEC 60332) Flame Propagation
Special Notes Where a conductor operates at a temperature exceeding 70C it shall be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
Min temperature for installation is +5degC.
6242/3Y
 Product Image
Datasheet
3D Model
Voltage Rating 300/500 volts
Description PVC Surface Wiring. For use in light industrial and domestic applications where the risk of mechanical damage is low. It may be clipped direct to a surface, on a tray, in free air or can be embedded in plaster. It is suitable for use within conduit where there is a greater risk of mechanical damage.
Construction Plain copper conductors, PVC insulated, cores laid flat with a non insulated circuit protective concuctor (cpc), PVC sheath.
Operating Temperature -15degC to +70degC
Minimum Bending Radius 3x 1 to 1.5sq 2 core
4x 2.5 to 16sq 2 core
4x 1 to 6sq 3 core
6x 10 to 16sq 3 core
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy.
Lengths 50/100/500m 1.5 - 6.0
50/100m 10.0 -16.0.
Sheath Colour Grey
Manufacturing Standard BS6004 Table 4
IS201-4 Table 1
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes Min temperature for installation is +5degC
6491B (H07Z-R)
BASEC
 Product Image
Datasheet
Approval  
3D Model
Voltage Rating 450/750 volts
Description Low Smoke Zero Halogen (LSZH) Conduit Wiring. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. Primarily for use within conduit or trunking but may also be used where suitable protection against mechanical damage exists eg within light fittings, switchgear and control gear.
Construction Stranded plain copper conductors, LSZH insulation
Operating Temperature -15degC to +90degC
Minimum Bending Radius 3x 1.5sq to 25sq
4x 35sq to 185sq
6x 240 to 630sq
Core Identification Bn, Be, Bk, Gy, Gn/Yw, Rd, We
Lengths 100/500m. Special lengths available on request
Sheath Colour N/A
Manufacturing Standard BS EN 50525-3-41 Table B1
Code of Practice/
Guide to Use
BS 7540
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265 (IEC 60332) Flame Propagation
Special Notes Where a conductor operates at a temperature exceeding 70C it shall be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
Min temperature for installation is +5degC
6491X (H07V-U solid H07V-R stranded)
BASEC
 Product Image
Datasheet
Approval  
3D Model
Voltage Rating 450/750 volts
Description PVC Conduit Wiring. Primarily for use within conduit or trunking but may also be used where suitable protection against mechanical damage exists eg within light fittings, switchgear and control gear.
Construction Solid or stranded plain copper conductors, single core, PVC insulation
Operating Temperature -15degC to +70degC
Minimum Bending Radius 3x 1.5sq to 25sq
4x 35sq to 240sq
6x 300 to 630sq
Core Identification Bn, Be, Bk, Gy, Gn/Yw, Yw*, Rd. Oe, Pk, Te, Vt, We
Lengths 100/500m 1.5 - 4.0
50/100/500m 6.0 - 25
Special Lengths available on request
Sheath Colour N/A
Manufacturing Standard BS EN 50525-2-31 Table B1
Code of Practice/
Guide to Use
BS 7540
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50265
Special Notes yellow is a non harmonised colour to BS6004 2000 Table 4a only
Min temperature for installation is +5degC
8Print summary for selected product(s)
Print
Compare two selected products
Compare
8.7/15kV BS 6883 - Armoured (Radial field)
Datasheet
Voltage Rating 8700/15000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH bedding, single core TPBB or three core GSWB, LSZH sheathed.
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 56, 57
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
8.7/15kV BS 6883 - Unarmoured (Radial field)
Datasheet
Voltage Rating 8700/15000 volts
Description Medium voltage elastomeric insulated cables for fixed wiring in ships and on mobile offshore units. Suitable for use in power and control applications.
Construction Stranded tinned copper conductor, semi conducting screen, elastomer insulated, semi conducting insulation screen, plain copper tape, single or three core, LSZH sheathed
Operating Temperature -30degC to +90degC
Minimum Bending Radius 20x diameter single core
15x diameter three core
Core Identification 1 core Bk
3 core Rd, Yw, Be
Sheath Colour Red
Manufacturing Standard BS6883 Table 54, 55
Code of Practice/
Guide to Use
IEE REGULATIONS for the ELECTRICAL and ELECTRONIC EQUIPMENT OF SHIPS
Fire Tests N/A
Emissions and
Flame Propagation
BS4066 (IEC60332) Flame propagation
BS7622 (IEC61034) Smoke Emission
BS6425 (IEC60754) Acid gas Emission
Special Notes SW4 LSZH sheaths offered as standard. Alternative SW2 CSP sheath available on request.
Min temperature for installation is -15degC
APrint summary for selected product(s)
Print
Compare two selected products
Compare
Accessories
Datasheet
Manufacturing Standard BS EN 60702-2
BPrint summary for selected product(s)
Print
Compare two selected products
Compare
BCS 295 Pt 1 0.6/1.0KV
Datasheet
Voltage Rating 600/1000 volts
Description PVC insulated, wire armoured power distribution cables.
Construction Stranded plain copper conductors, PVC insulated, cores layed up, PVC bedding, GSW armour, PVC shearth
Operating Temperature -10degC to +70degC
Minimum Bending Radius 6x cable diameter.
Core Identification 2 core rd, bk
3 core rd, yw, be
4 core rd, yw, be, bk
Sheath Colour Black
Manufacturing Standard BCS295 Part 1
Special Notes Minimum temperature for installation purposes is 0degC
BCS 643 Pull Cables
Datasheet
Voltage Rating 300/500 volts
Description Steel wire braided cables used for communication and control for haulage and conveyor systems
Construction Tinned copper stranded conductors, PVC insulated, tinned copper wire screen optional, cores laid up, PVC bedding, brass plated steel wire braid, PVC sheath
Operating Temperature -10degC to +70degC
Minimum Bending Radius 6x cable diameter.
Core Identification 2 core be, bk
4 core be, bk, rd, yw
6 core rd, yw, gn, bk, be, we
Sheath Colour Rd, yw or gn
Manufacturing Standard BCS 643 Pull Cables
BCS 648 Minewinder Safety Cables
Datasheet
Voltage Rating 600/1000 volts
Description Multicore armoured cables with special screening for minwinder safety and control circuits
Construction Plain copper stranded conductors, PVC insulated, spiral plain copper screen, cores laid up, PVC bedding, GSW armoured, PVC sheathed
Operating Temperature -10degC to +70degC
Minimum Bending Radius 6x cable diameter.
Core Identification 2 core rd, bk
4 core rd, yw, be, bk
6 core numbered
8 core numbered
Sheath Colour Black
Manufacturing Standard BCS 648 Minewinder Safety Cables
BS6195 Type 4A
Datasheet
3D Model
Voltage Rating 300/500 volts
Description Rubber insulated, flame retardant, flexible cables for use as coil end leads that are connected directly and permanently to a coil winding or other component of electrical apparatus. Suitable for use where the maximum voltage, between conductors or between conductors and earth, to which the cable is liable to be subjected during a 1 minute test of the equipment to which it is connected does not exceed 2.5kV
Construction Flexible tinned copper conductors, composite insulation
Operating Temperature -15degC to +90degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification Natural
Sheath Colour Bk, Be, Bn, Rd, We, Yw, Gn/Yw, Gn
Manufacturing Standard BS6195 Type 4A
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
BS6195 Type 4C
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description Rubber insulated, flame retardant, flexible cables for use as coil end leads that are connected directly and permanently to a coil winding or other component of electrical apparatus. Suitable for use where the maximum voltage, between conductors or between conductors and earth, to which the cable is liable to be subjected during a 1 minute test of the equipment to which it is connected does not exceed 4kV
Construction Flexible tinned copper conductors, composite insulation
Operating Temperature -15degC to +90degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification Natural
Sheath Colour Bk, Be, Oe, We
Manufacturing Standard BS6195 Type 4C
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
BS6195 Type 4D
Datasheet
3D Model
Voltage Rating 1900/3300 volts
Description Rubber insulated, flame retardant, flexible cables for use as coil end leads that are connected directly and permanently to a coil winding or other component of electrical apparatus. Suitable for use where the maximum voltage, between conductors or between conductors and earth, to which the cable is liable to be subjected during a 1 minute test of the equipment to which it is connected does not exceed 9.5kV
Construction Flexible tinned copper conductors, composite insulation
Operating Temperature -15degC to +90degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification Natural
Sheath Colour Black
Manufacturing Standard BS6195 Type 4D
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
BS6195 Type 4E
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description Rubber insulated, flame retardant, flexible cables for use as coil end leads that are connected directly and permanently to a coil winding or other component of electrical apparatus. Suitable for use where the maximum voltage, between conductors or between conductors and earth, to which the cable is liable to be subjected during a 1 minute test of the equipment to which it is connected does not exceed 17kV
Construction Flexible tinned copper conductors, composite insulation
Operating Temperature -15degC to +90degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification Natural
Sheath Colour Black
Manufacturing Standard BS6195 Type 4E
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
BS6195 Type 4F
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description Rubber insulated, flame retardant, flexible cables for use as coil end leads that are connected directly and permanently to a coil winding or other component of electrical apparatus. Suitable for use where the maximum voltage, between conductors or between conductors and earth, to which the cable is liable to be subjected during a 1 minute test of the equipment to which it is connected does not exceed 27kV
Construction Flexible tinned copper conductors, composite insulation
Operating Temperature -15degC to +90degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification Natural
Sheath Colour Black
Manufacturing Standard BS6195 Type 4F
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
BS6708 Type 11 0.64/1.1KV
Datasheet
Voltage Rating 640/1100 volts
Description Flexible trailing cable for use with shuttle cars, coal cutters and similar face equipment
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores plus 1 copper/nylon screened pilot core laid around a PCP centre, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, pilot be
Sheath Colour Black
Manufacturing Standard BS6708 Type 11
BS6708 Type 201 0.64/1.1KV
Datasheet
Voltage Rating 640/1100 volts
Description Flexible trailing cables with galvanised steel pliable wire armouring for use as mine roadway extension cables and mechanically protected trailing cables in quaries and coal face lighting.
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores laid around a PCP centre, PCP bedding, Galvanised steel wire armour, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn
Sheath Colour Black with yellow stripe
Manufacturing Standard BS6708 Type 201
BS6708 Type 211 0.64/1.1KV
Datasheet
Voltage Rating 640/1100 volts
Description Flexible trailing cables with galvanised steel pliable wire armouring for use as mine roadway extension cables and mechanically protected trailing cables in quaries and coal face lighting.
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores and one insulated flexible tinned copper earth conductor laid around a PCP centre, PCP bedding, galvanised steel wire armour, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, gn/yw
Sheath Colour Black with yellow stripe
Manufacturing Standard BS6708 Type 211
BS6708 Type 307 1.9/3.3KV
Datasheet
Voltage Rating 1900/3300 volts
Description Flexible trailing cable for use with coal cutters and similar face equipment
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores plus 1 unscreened pilot core laid around a bare earth conductor, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, pilot be
Sheath Colour Black with red stripe
Manufacturing Standard BS6708 Type 307
BS6708 Type 307M 1.9/3.3KV
Datasheet
3D Model
Voltage Rating 1900/3300 volts
Description Flexible trailing cable for use with coal cutters and similar face equipment
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores plus 1 copper/nylon screened pilot core laid around a bare earth conductor, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, pilot be
Sheath Colour Black with red stripe
Manufacturing Standard BS6708 Type 307M
BS6708 Type 307S 1.9/3.3KV
Datasheet
Voltage Rating 1900/3300 volts
Description Flexible trailing cable for use with coal cutters and similar face equipment
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores plus 1 unscreened pilot unit laid around a bare earth conductor, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, pilot unit be
Sheath Colour Black with red stripe
Manufacturing Standard BS6708 Type 307S
BS6708 Type 321 1.9/3.3KV
Datasheet
Voltage Rating 1900/3300 volts
Description Flexible trailing cables with galvanised steel pliable wire armouring for use as mine roadway extension cables and mechanically protected trailing cables in quaries.
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 power cores and one insulated earth conductor laid around a PCP centre, PCP bedding, galvanised steel wire armour, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, gn/yw
Sheath Colour Black with blue stripe
Manufacturing Standard BS6708 Type 321
BS6708 Type 331 1.9/3.3KV
Datasheet
Voltage Rating 1900/3300 volts
Description Flexible trailing cables with galvanised steel pliable wire armouring for use as mine roadway extension cables and mechanically protected trailing cables in quaries.
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores and one insulated earth conductor laid around a PCP centre, PCP bedding, galvanised steel wire armour, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, gn/yw
Sheath Colour Black with blue stripe
Manufacturing Standard BS6708 Type 331
BS6708 Type 631 3.8/6.6KV
Datasheet
Voltage Rating 3800/6600 volts
Description Flexible trailing cables with galvanised steel pliable wire armouring for use as mine roadway extension cables and mechanically protected trailing cables in quaries.
Construction Flexible tinned annealed copper conductors, semi-con MEPR insulated, 3 copper/nylon screened power cores and one insulated earth conductor laid around a PCP centre, PCP bedding, galvanised steel wire armour, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, gn/yw
Sheath Colour Black with red stripe
Manufacturing Standard BS6708 Type 631
BS6708 Type 7 0.64/1.1KV
Datasheet
Voltage Rating 640/1100 volts
Description Flexible trailing cable for use with coal cutters and similar face equipment
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores plus 1 unscreened pilot core laid around a flexible tinned copper bare earth, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, pilot be
Sheath Colour Black
Manufacturing Standard BS6708 Type 7
BS6708 Type 7M 0.64/1.1KV
Datasheet
Voltage Rating 640/1100 volts
Description Flexible trailing cable for use with coal cutters and similar face equipment
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores plus 1 screened pilot core laid around a flexible tinned copper bare earth, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, pilot be
Sheath Colour Black
Manufacturing Standard BS6708 Type 7M
BS6708 Type 7S 0.64/1.1KV
Datasheet
Voltage Rating 640/1100 volts
Description Flexible trailing cable for use with coal cutters and similar face equipment
Construction Flexible tinned annealed copper conductors, MEPR insulated, 3 copper/nylon screened power cores plus 1 screened pilot unit containing three pilot cores laid around a flexible tinned copper bare earth, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Rd, yw, bn, pilot unit be
Sheath Colour Black
Manufacturing Standard BS6708 Type 7
BS6708 Types 506 512 518 524
Datasheet
Voltage Rating 320/550 volts
Description Flexible multicore auxilliary cables with galvanised steel pliable wire armouring to provide remote control circuits and for interconnections between machine sections and associated auxilliary equipment.
Construction Flexible tinned annealed copper conductors, ETFE insulated, TCWB, 6 12 18 or 24 cores laid up, PCP bedding, galvanised steel wire armour, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Type 506 rd ,yw ,be , bk, gn, bn
Type 512 2 rd, 2 yw, 2 be, bk, gn, bn, we, oe, gy
Type 518 2 rd, 2 yw, 2 be, 2 bk, 2 gn, 2 bn, 2 we, 2 oe, 2 gy
Type 524 3 rd, 3 yw, 3 be, 3 bk, 3 gn, 3 bn, 2 we, 2 oe, 2 gy
Sheath Colour Black
Manufacturing Standard BS6708 Types 506 512 518 524
BS6708 Types 62 63 64 0.64/1.1KV
Datasheet
Voltage Rating 640/1100 volts
Description Flexible trailing cables with galvanised steel pliable wire armouring for use as mine roadway extension cables and mechanically protected trailing cables in quaries and coal face lighting.
Construction Flexible tinned annealed copper conductors, MEPR insulated, copper/nylon screened power cores laid around a PCP centre, PCP bedding, Galvanised steel wire armour, HD sheath.
Operating Temperature -25degC to +75degC
Minimum Bending Radius 6x cable diameter.
Core Identification Type 61 bn, be
Type 63 bn, be, rd
Type 64 bn, be rd, yw
Sheath Colour Black
Manufacturing Standard BS6708 Types 62, 63, 64
CPrint summary for selected product(s)
Print
Compare two selected products
Compare
Clip Sizes
Datasheet
EPrint summary for selected product(s)
Print
Compare two selected products
Compare
EN50264-2-1 Standard Wall 0.6/1.0V single core
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Standard wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits, electric heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation
Operating Temperature -25C to +90C EI101, EI103
-40C to +90C EI102, EI104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50264-2-1 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-1 Standard Wall 1.8/3kV single core
Datasheet
Voltage Rating 1.8/3kV volts
Description Standard wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include auxilliary circuits at line voltage, traction circuits, electric heating.
Construction Flexible tinned copper conductors, LFH Insulation
Operating Temperature -25C to +90C EI101, EI103
-40C to +90C EI102, EI104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50264-2-1 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-1 Standard Wall 1.8/3kV single core, sheathed
Datasheet
Voltage Rating 1.8/3kV volts
Description Standard wall single core, sheathed cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include auxilliary circuits at line voltage, traction circuits, electric heating circuits on exposed trays.
Construction Flexible tinned copper conductors, LFH Insulation and sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour Black
Manufacturing Standard EN50264-2-1 Table 3
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-1 Standard Wall 3.6/6kV single core, sheathed
Datasheet
Voltage Rating 3.6/6kV volts
Description Standard wall singlecore, sheathed cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include auxilliary circuits at line voltage, traction circuits, electric heating circuits on exposed trays.
Construction Flexible tinned copper conductors, LFH Insulation and sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour Black
Manufacturing Standard EN50264-2-1 Table 4
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-2 Standard Wall 0.3/0.5kV multicore
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Standard wall multicore cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black with numbers
(see note 1)
Sheath Colour Black
Manufacturing Standard EN50264-2-2 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
Special Notes Note 1. A green yellow earth core can be substituted for one of the black cores in the outer layer if required.
EN50264-2-2 Standard Wall 0.3/0.5kV multicore, screened
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Standard wall multicore, screened cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, tinned copper wire braid, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 10x cable diameter
Core Identification Black with numbers (see note 1)
Sheath Colour Black
Manufacturing Standard EN50264-2-2 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
Special Notes Note 1. A green yellow earth core can be substituted for one of the black cores in the outer layer if required.
EN50264-2-2 Standard Wall 0.6/1.0kV multicore
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Standard wall multicore cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black with numbers
Sheath Colour Black
Manufacturing Standard EN50264-2-2 Tables 4,6,8
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-2-2 Standard Wall 0.6/1.0kV multicore, screened
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Standard wall multicore, screened cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, tinned copper wire braid, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 10x cable diameter
Core Identification Black with numbers
Sheath Colour Black
Manufacturing Standard EN50264-2-2 Tables 5,7,9
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-1 Reduced Wall 0.6/1.0V single core
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Reduced wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits, electric heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation
Operating Temperature -25C to +90C EI106, EI108
-40C to +90C EI107, EI109
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50264-3-1 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-1 Reduced Wall 1.8/3V single core
Datasheet
Voltage Rating 1.8/3kV volts
Description Reduced wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include power and heating circuits.
Construction Flexible tinned copper conductors, LFH Insulation
Operating Temperature -25C to +90C EI106, EI108
-40C to +90C EI107, EI109
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50264-3-1 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagatio
EN50305 Toxicity
EN50264-3-1 Reduced Wall 1.8/3V single core, sheathed
Datasheet
Voltage Rating 1.8/3kV volts
Description Reduced wall single core, sheathed cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include power and heating circuits.
Construction Flexible tinned copper conductors, LFH Insulation and sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour Black
Manufacturing Standard EN50264-3-1 Table 3
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-1 Reduced Wall 3.6/6V single core, sheathed
Datasheet
Voltage Rating 3.6/6kV volts
Description Reduced wall single core, sheathed cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include power and heating circuits.
Construction Flexible tinned copper conductors, LFH Insulation and sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black
Sheath Colour Black
Manufacturing Standard EN50264-3-1 Table 4
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-2 Reduced Wall 0.3/0.5kV multicore
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Reduced wall multicore cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black with numbers (see note 1)
Sheath Colour Black
Manufacturing Standard EN50264-3-2 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
Special Notes Note 1. A green yellow earth core can be substituted for one of the black cores in the outer layer if required.
EN50264-3-2 Reduced Wall 0.3/0.5kV multicore, screened
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Reduced wall multicore, screened cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, tinned copper wire braid, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 10x cable diameter
Core Identification Black with numbers (see note 1)
Sheath Colour Black
Manufacturing Standard EN50264-3-2 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
Special Notes Note 1. A green yellow earth core can be substituted for one of the black cores in the outer layer if required.
EN50264-3-2 Reduced Wall 0.6/1.0kV multicore
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Reduced wall multicore cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification Black with numbers
Sheath Colour Black
Manufacturing Standard EN50264-3-2 Tables 4,6,8
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50264-3-2 Reduced Wall 0.6/1.0kV multicore, screened
Datasheet
Voltage Rating 0.6/1.0kV volts
Description Reduced wall multicore, screened cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting heating and power circuits.
Construction Flexible tinned copper conductors, LFH Insulation, cores layed up, tinned copper wire braid, LFH sheath
Operating Temperature -25C to +90C EM101, EM103
-40C to +90C EM102, EM104
Minimum Bending Radius 10x cable diameter
Core Identification Black with numbers
Sheath Colour Black
Manufacturing Standard EN50264-3-2 Tables 5,7,9
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50264 Halogens
EN61034 Smoke Emission
EN60332, EN50266, EN50305 Flame propagation
EN50305 Toxicity
EN50306-2 Thin Wall 0.3/0.5kV single core
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits, internal wiring of equipment.
Construction Stranded tinned copper conductor, LFH insulation
Operating Temperature -25C to +105C
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification White
Sheath Colour N/A
Manufacturing Standard EN50306-2 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-3 Thin Wall 0.3/0.5kV single and multicore, screened
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall single core and multicore screened cables for use in rolling stock as fixed wiring or where there is limited flexing. Applications include control and monitoring circuits, interlocking circuits, indicating circuits, internal wiring of equipment.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screen, LFH sheath
Operating Temperature -25C to +90C S2
-40C to +105C S1
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-3 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multicore, screen, std wall sheath class E
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall, screened, multicore cables with standard wall sheaths for use in exposed situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screen, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 3 (E)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multicore, screened, std wall sheath class P
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall, screened, multicore cables with standard wall sheaths for use in protected situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screen, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 3 (P)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multicore, std wall sheath class E
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall multicore cables with standard wall sheaths for use in exposed situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include control and monitoring circuits, interlocking circuits, indicating circuits, internal wiring run on exposed trays.
Construction Stranded tinned copper conductor, LFH insulation, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 1 (E)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multicore, std wall sheath class P
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall multicore cables with standard wall sheaths for use in protected situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include control and monitoring circuits, interlocking circuits, indicating circuits, internal wiring of equipment.
Construction Stranded tinned copper conductor, LFH insulation, LFH sheath
Operating Temperature -25C to +90C S2
-40C to +105C S1
Minimum Bending Radius 4x D if D is <12mm dia
5x D if D is >12mm dia
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 1 (P)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multipair, ind screen, std wall sheath class E
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall, individually screened, multipair cables with standard wall sheaths for use in exposed situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screened pairs, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 5 (E)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50306-4 Thin Wall 0.3/0.5kV multipair, ind screen, std wall sheath class P
Datasheet
Voltage Rating 0.3/0.5kV volts
Description Thin wall, individually screened, multipair cables with standard wall sheaths for use in protected situations in rolling stock. Used as fixed wiring or where there is limited flexing. Applications include lighting circuits, control and monitoring circuits.
Construction Stranded tinned copper conductor, LFH insulation, tinned copper wire screened pairs, LFH sheath
Operating Temperature -25C to +90C S2, EM101,EM103
-40C to +90C EM102,EM104
Minimum Bending Radius 10x cable diameter
Core Identification White with numbers
Sheath Colour Black
Manufacturing Standard EN50306-4 Table 5 (P)
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684 Halogens
EN50268 Smoke Emission
EN50265, EN50266, EN60305 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 1.8/3kV single core
Datasheet
Voltage Rating 1.8/3kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction and power circuits
Construction Flexible copper conductors, LFH Insulation (optional braid)
Operating Temperature -40C to +120C tinned coppe
r -40C to +150C plain copper
Minimum Bending Radius 10x cable diameter
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50382-2 Table 1
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 1.8/3kV single core, sheathed
Datasheet
Voltage Rating 1.8/3kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction and power circuits
Construction Flexible copper conductors, LFH Insulation, LFH sheath
Operating Temperature -25C to +120C EM105
-40C to +120C EM106
-40C to +150C EM107
Minimum Bending Radius 10x cable diameter
Core Identification White
Sheath Colour black
Manufacturing Standard EN50382-2 Table 2
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 3.6/6kV single core
Datasheet
Voltage Rating 3.6/6kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction and power circuits
Construction Flexible copper conductors, LFH Insulation (optional braid)
Operating Temperature -40C to +120C tinned copper
-40C to +150C plain copper
Minimum Bending Radius 10x cable diameter
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50382-2 Table 3
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 3.6/6kV single core (class 6, enhanced insulation)
Datasheet
Voltage Rating 3.6/6kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction, power and inter coach power circuits.
Construction Flexible class 6 copper conductors, LFH Insulation (optional braid)
Operating Temperature -40C to +120C tinned copper
-40C to +150C plain copper
Minimum Bending Radius 10x cable diameter
Core Identification Black
Sheath Colour N/A
Manufacturing Standard EN50382-2 Table 4
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
EN50382-2 High Temperature 3.6/6kV single core, sheathed
Datasheet
Voltage Rating 3.6/6kV volts
Description High temperature single core cable for use in rolling stock as fixed wiring or where there is limited flexing. Applications include traction and power circuits
Construction Flexible copper conductors, LFH Insulation, LFH sheath
Operating Temperature -25C to +120C EM105
-40C to +120C EM106
-40C to +150C EM107
Minimum Bending Radius 10x cable diameter
Core Identification White
Sheath Colour Black
Manufacturing Standard EN50382-2 Table 5
Code of Practice/
Guide to Use
EN50355
Fire Tests N/A
Emissions and
Flame Propagation
EN50267, EN60684, EN50382 Halogens
EN61034 Smoke Emission
EN60332, EN50266 Flame propagation
EN50305 Toxicity
FPrint summary for selected product(s)
Print
Compare two selected products
Compare
Firetec Enhanced
BASEC
LPCB
Cert No 221f/01
 Product Image
Datasheet
Approval   
3D Model
Voltage Rating 300/500 volts
Description Firetec Enhanced cable is suitable for fire alarm systems, BS5839-8 voice alarm systems, emergency lighting circuits & Category 1, 2 & 3 Control circuits as defined in BS8519. The mica glass tape is applied directly over the conductor to ensure the best possible enhanced fire performance. It meets enhanced grade as defined by BS5839-1 26.2e.
Construction Solid or stranded plain annealed copper conductors. Tinned annealed copper full size CPC. Mica/glass fire barrier tape. Aluminium/polyester laminated tape screen. LSZH insulation and outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 6 x overall diameter
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Lengths 100/500m
Special lengths available on request.
Sheath Colour Red or White. Other colours available.
Manufacturing Standard BS 7629-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5839-8
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 control see special notes)
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1 Testing at AEI Cables has confirmed that the cable complies with BS8519 Category 3 Control
. 2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
Firetec Enhanced
LUL
BASEC
LPCB
Cert No 221f/01
 Product Image
Datasheet
Approval   
3D Model
Voltage Rating 300/500 volts
Description Firetec Enhanced cable is suitable for fire alarm systems, BS 5839-8 voice alarm systems and BS5266-1 emergency lighting circuits & Category 1, 2 & 3 Control circuits as defined in BS8519. The mica glass tape is applied directly over the conductor to ensure the best possible enhanced fire performance. It meets enhanced grade as defined by BS5839-1 26.2e.
Construction Solid or stranded plain annealed copper conductors. Tinned annealed copper full size CPC. Mica/glass fire barrier tape. Aluminium/polyester laminated tape screen. LSZH insulation and outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 6 x overall diameter
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Lengths 100/500m
Special lengths available on request.
Sheath Colour Red or White. Other colours available.
Manufacturing Standard BS 7629-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5839-8
BS 5266
BS 8519 Category 1&2 Control
(for Category 3 control see special notes)
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
Emissions and
Flame Propagation
LUL 1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1 Testing at AEI Cables has confirmed that the cable complies with BS8519 Category 3 Control.
2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
Firetec FRF2
LUL
Datasheet
Approval
Voltage Rating 450/750 volts
Description Firetec FRF2 cable is a flexible cable suitable for use as an enhanced cable to BS5266 (emergency lighting), BS5839-1 (fire alarms), and BS5839-8 (voice alarms). It is suitable for use as a BS8519 category 2 control cable. It complies with the flex test in BS6500 to 32000 cycles flexing
Construction Flexible class 5 plain copper conductor, mica/glass fire barrier, LSZH insulation, LSZH sheath
Operating Temperature -25degC to +90degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification 3 core Bn, Be, Gn/Yw
4 core Bn, Bk, Gy, Gn/Yw
Lengths 100m
longer lengths on request
Sheath Colour White
Manufacturing Standard BS6500(Generally to, fire resistant)
Code of Practice/
Guide to Use
BS 5266-1
BS 5839-1
BS 5839-9
BS 8519 Cat 2 Control
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
IEC 331-3 120mins in conduit
Emissions and
Flame Propagation
LUL 1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Methods of cable support should withstand a similar temperature and duration to that of the cable.
Firetec Impact Power
BASEC
LPCB
 Product Image
Datasheet
Approval     
3D Model
Voltage Rating 600/1000 volts
Description Firetec Impact Power cables are similar in construction to armoured cables, but provide additional protection to smaller cable sizes to ensure the best possible mechanical protection from a polymeric cable. Designed to meet the application of fire, direct impact and water jet as specified in BS8491, making them suitable for use as 120 minute rated category 3 power cables under BS8519.
Construction Stranded plain annealed copper conductors. Mica/glass fire barrier tape. Cross linked polyethylene insulation (XLPE). LSZH bedding, steel wire armouring and LSZH outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 8 x overall diameter
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard BS 7846
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 7346
BS 8519 Category 1, 2, 3 Control
and Category 1, 2, 3 Power
BS9999
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS6387 C W & Z
BS8491 F120
BS7846 F2 F120
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1. Old core colours available. 2c Rd, Blk. 3c Rd, Yw, Be. 4c Rd, Yw, Be, Blk.
2. Methods of cable support should withstand a similar temperature and duration to that of the cable.
Firetec Impact Power
LUL
BASEC
LPCB
 Product Image
Datasheet
Approval      
3D Model
Voltage Rating 600/1000 volts
Description Firetec Impact Power cables are similar in construction to armoured cables, but provide additional protection to smaller cable sizes to ensure the best possible mechanical protection from a polymeric cable. Designed to meet the application of fire, direct impact and water jet as specified in BS8491, making them suitable for use as 120 minute rated category 3 power cables under BS8519.
Construction Stranded plain annealed copper conductors. Mica/glass fire barrier tape. Cross linked polyethylene insulation (XLPE). LSZH bedding, steel wire armouring and LSZH outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 8 x overall diameter
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard BS 7846
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 7346
BS 8519 Category 1, 2, 3 Control
and Category 1, 2, 3 Power
BS9999
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS6387 C W & Z
BS8491
Emissions and
Flame Propagation
LUL 1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265 (IEC 60332) Flame Propagation
Special Notes 1. Old core colours available. 2c Rd, Blk. 3c Rd, Yw, Be. 4c Rd, Yw, Be, Blk.
2. Methods of cable support should withstand a similar temperature and duration to that of the cable.
Firetec Power
BASEC
LPCB
Cert No 221k/01
 Product Image
Datasheet
Approval    
3D Model
Voltage Rating 600/1000 volts
Description Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm systems & emergency lighting systems. It is robust, flexible and suitable for use inside and outside buildings, meeting the enhanced grade of BS5839 26.2e.
Construction Stranded plain annealed copper conductors. Mica/glass fire barrier tape. Cross linked polyethylene insulation (XLPE). LSZH bedding, steel wire armouring and LSZH outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 6 x overall diameter
8 x for 25mm² and above
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Multicore - white cores with black printed numbers
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard BS 7846
Code of Practice/
Guide to Use
BS5266
See special notes below
Fire Tests BS 6387 C W & Z
BS 7846 F2
BS 8434-2
BS EN 50200 PH30, PH60, PH120
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1. Old core colours available. 2c Rd, Blk. 3c Rd, Yw, Be. 4c Rd, Yw, Be, Blk.
2. This cable can be supplied without steel wire armour for situations where sufficient mechanical protection already exists and where a smaller, lighter, more flexible cable would be preferred. Simply request details of our Firetec Unarmoured range of cables. Fire resistant to BS 6387 C W & Z, LSZH material used throughout, LPCB approved.
3. Methods of cable support should withstand a similar temperature and duration to that of the cable
. 4. Testing at AEI confirms compliance with BS8519 Category 1, 2 & 3 Control and meets the requirements for an enhanced grade of cable to BS5839 26.2e.
Firetec Power
LUL
BASEC
LPCB
Cert No 221k/01
 Product Image
Datasheet
Approval    
3D Model
Voltage Rating 600/1000 volts
Description Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm systems & emergency lighting systems. It is robust, flexible and suitable for use inside and outside buildings, meeting the enhanced grade of BS5839 26.2e.
Construction Stranded plain annealed copper conductors. Mica/glass fire barrier tape. Cross linked polyethylene insulation (XLPE). LSZH bedding, steel wire armouring and LSZH outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 6 x overall diameter
8 x for 25mm² and above
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Multicore - white cores with black printed numbers
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard BS 7846
Code of Practice/
Guide to Use
BS5266 See special notes below
Fire Tests BS 6387 C W & Z
BS 7846 F2
BS 8434-2
BS EN 50200 PH30, PH60, PH120
Emissions and
Flame Propagation
LUL 1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1. Old core colours available. 2c Rd, Blk. 3c Rd, Yw, Be. 4c Rd, Yw, Be, Blk.
2. This cable can be supplied without steel wire armour for situations where sufficient mechanical protection already exists and where a smaller, lighter, more flexible cable would be preferred. Simply request details of our Firetec Unarmoured range of cables. Fire resistant to BS 6387 C W & Z, LSZH material used throughout, LPCB approved.
3. Methods of cable support should withstand a similar temperature and duration to that of the cable.
4. Testing at AEI confirms compliance with BS8519 Category 1, 2 & 3 Control and meets the requirements for an enhanced grade of cable to BS5839 26.2e.
Firetec Single
LPCB
Cert No 221c/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 600/1000 volts
Description Firetec Singlecore is designed to be installed in metal conduit, trunking and other cable containment systems. For use in alarm, emergency lighting and other circuits for new installations or upgrading existing conduit systems to fire performance standards. Elastomeric insulation gives high mechanical strength, excellent flexibility and resistance to abrasion.
Construction Stranded plain annealed copper conductors. Mica/glass fire barrier tape. Elastomeric LSZH outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 6 x overall diameter
Core Identification Bn, Bk, Gy, Be, Rd, Oe, Yw, Gn/Yw. Other colours available on request.
Lengths 100/500m
Special lengths available on request.
Sheath Colour N/A
Manufacturing Standard BS7211 (Generally to , fire resistant)
Code of Practice/
Guide to Use
N/A
Fire Tests BS 6387 C, W, Z
IEC 60331-21
BS EN 50200 PH120
BS 8434-2 when tested in a steel conduit at a temperature of 950ºC and an increased voltage of 600/1000volts.
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Methods of cable support should withstand a similar temperature and duration to that of the cable.
Firetec Single
LPCB
Cert No 221c/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 600/1000 volts
Description Firetec Singlecore is designed to be installed in metal conduit, trunking and cable management systems. For use in alarm, emergency lighting and other circuits for new installations or upgrading existing conduit systems to fire performance standards. Elastomeric insulation gives high mechanical strength, excellent flexibility and resistance to abrasion.
Construction Stranded plain annealed copper conductors. Mica/glass fire barrier tape. Elastomeric LSZH outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 6 x overall diameter
Core Identification Bn, Bk, Gy, Be, Rd, Oe, Yw, Gn/Yw. Other colours available on request.
Lengths 100/500m
Special lengths available on request.
Sheath Colour N/A
Manufacturing Standard BS7211 (Generally to , fire resistant)
Code of Practice/
Guide to Use
N/A
Fire Tests BS 6387 C, W, Z
IEC 60331-21
BS EN 50200 PH120
BS 8434-2 when tested in a steel conduit at a temperature of 950ºC and an increased voltage of 600/1000volts.
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Methods of cable support should withstand a similar temperature and duration to that of the cable
.
Firetec Standard
BASEC
LPCB
Cert No 221e/01
 Product Image
Datasheet
Approval   
3D Model
Voltage Rating 300/500 volts
Description Firetec Standard cable is suitable for fire alarm systems, emergency lighting and BS 5839-8 voice alarm systems. It meets the standard grade of BS 5839 26.2d & Category 1 Control as defined by BS8519.
Construction Solid or stranded plain annealed copper conductors. Tinned annealed copper full size CPC. Aluminium/polyester laminated tape screen. LSZH insulation and outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 6 x overall diameter
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Lengths 100/500m
Special lengths available on request.
Sheath Colour Red or White. Other colours available.
Manufacturing Standard BS 7629-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2d Standard
BS5839-8
BS 5266
BS 8519 Category 1 Control
Fire Tests BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Methods of cable support should withstand a similar temperature and duration to that of the cable.
Firetec Standard
LUL
BASEC
LPCB
Cert No 221e/01
 Product Image
Datasheet
Approval   
3D Model
Voltage Rating 300/500 volts
Description Firetec Standard cable is suitable for fire alarm systems, emergency lighting circuits and BS5839-8 voice alarm systems. It meets the standard grade of BS 5839 26.2d, BS5266-1 & Category 1 Control as defined by BS8519.
Construction Solid or stranded plain annealed copper conductors. Tinned annealed copper full size CPC. Aluminium/polyester laminated tape screen. LSZH insulation and outer sheath.
Operating Temperature -10degC to +90degC
Minimum Bending Radius 6 x overall diameter
Core Identification 2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Lengths 100/500m
Special lengths available on request.
Sheath Colour Red or White. Other colours available.
Manufacturing Standard BS 7629-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2d Standard
BS 5839-8
BS 5266
BS 8519 Category 1 Control
Fire Tests BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
Emissions and
Flame Propagation
LUL 1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Methods of cable support should withstand a similar temperature and duration to that of the cable.
GPrint summary for selected product(s)
Print
Compare two selected products
Compare
G4726 (formerly EME-SP-14-026)
LUL
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description Single core LFH conduit wire
Construction Stranded plain copper conductors, LSZH insulation
Operating Temperature -15degC to +90degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Bn, Be, Bk, Gy, Gn/Yw, Rd, We
G4726 (formerly EME-SP-14-026)
Datasheet
Voltage Rating 450/750 volts
Description Singlecore LSZH cable for LV power and dc traction supply.
Construction Stranded copper conductors, LSZH insulation
Operating Temperature -20degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Bn, Be, Bk, Gy, Gn/Yw, Rd, We
Sheath Colour N/A
Manufacturing Standard G4726
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G4727 (formerly EME-SP-14-027)
LUL
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description LFH armoured cable.
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, LSZH bedding, SWA, LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 8x cable diameter
Core Identification 2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
G4727 (formerly EME-SP-14-027)
LUL
 Product Image
Datasheet
Approval   
Voltage Rating 600/1000 volts
Description Single and multicore LSZH armoured power cables
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, LSZH bedding, single core AWA 2 or more cores SWA, LSZH sheath.
Operating Temperature -20degC to +85degC
Minimum Bending Radius 8x cable diameter
Core Identification 1 core Bn or Be
2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
Sheath Colour Black
Manufacturing Standard G4727
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G4727 (formerly EME-SP-14-027)+FR
LUL
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description Fire resistant LFH armoured cable
Construction Stranded plain copper conductors, mica glass tape, XLPE insulation, cores laid up, LSZH bedding, SWA, LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 8x cable diameter
Core Identification 2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
Sheath Colour Black
Manufacturing Standard G4727+FR
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Fire Tests BS 6387 C W & Z
BS 7846 F2
BS 8434-2
BS EN 50200 PH30, PH60, PH120
Emissions and
Flame Propagation
LUL 1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
G7250 Type D1
Datasheet
Voltage Rating 650/1100 volts
Description Single core signalling cables
Construction Singlcore tinned copper solid or stranded conductor, LFH sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 2x cable diameter <= 10mm
3x cable diameter 10 - 25mm
6x cable diameter >25mm
Core Identification Black
Sheath Colour Black
Manufacturing Standard G7250
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G7250 Type D2
Datasheet
Voltage Rating 650/1100 volts
Description Twin and multicore screened signalling cables
Construction Twin and multicore tinned copper solid or stranded conductor, insulated, cores laid up, aluminium taped spiral wire screened, sheathed
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black numbered
Sheath Colour Black
Manufacturing Standard G7250
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G7250 Type E1
Datasheet
Voltage Rating 650/1100 volts
Description Flexible singlecore signalling cables
Construction Singlcore tinned copper flexible conductor, LFH sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 2xcable diameter <= 10mm
3xcable diameter 10 - 25mm
6xcable diameter >25mm
Core Identification Black
Sheath Colour Black
Manufacturing Standard G7250
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G7250 Type E2
Datasheet
Voltage Rating 650/1100 volts
Description Flexible twin and multicore screened signalling cables
Construction Twin and multicore tinned copper flexible conductor, insulated, cores laid up, aluminium taped spiral wire screened, sheathed.
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black numbered
Sheath Colour Black
Manufacturing Standard G7250
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
G7622
Voltage Rating 110 volts
Description Multi-pair trackside communications with moisture barrier.
Construction Solid tinned copper wire, cellular PE insulation, cores laid up, aluminiumPETP moisture barrier tape, LSZH sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Sheath Colour Violet
Manufacturing Standard G7622
Code of Practice/
Guide to Use
E4156 Part 1
S1121
G7624
Voltage Rating 750 volts
Description Track side twisted screened pair signalling cables
Construction Tinned copper strand, insulated, paired, screened, sheathed
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Blue/white
Sheath Colour Black
Manufacturing Standard G7624
Code of Practice/
Guide to Use
E4156 Part 1
S1121
LPrint summary for selected product(s)
Print
Compare two selected products
Compare
LSZH Low Voltage 0.6/1.0kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description LSZH Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Solid aluminium conductors, XLPE insulation, cores laid up, LSZH bedding, single core AWA 2 or more cores SWA, LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 8 x overall diameter
Core Identification 1 core Bn or Be
2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
5 core Gn/Yw, Be, Bn, Bk, Gy
Multicore - white cores with black printed numbers
Sheath Colour Black
Manufacturing Standard BS 6724
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Low Voltage 0.6/1.0kV Copper
BASEC
LUL
 Product Image
Datasheet
Approval   
3D Model
Voltage Rating 600/1000 volts
Description LSZH Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, LSZH bedding, single core AWA 2 or more cores SWA, LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 6x circular conductors
8x shaped conductors
Core Identification 1 core Bn or Be
2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
5 core Gn/Yw, Be, Bn, Bk, Gy
Multicore - white cores with black printed numbers
Sheath Colour Black
Manufacturing Standard BS 6724
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Low Voltage 0.6/1.0kV Copper
LUL
BASEC
 Product Image
Datasheet
Approval   
3D Model
Voltage Rating 600/1000 volts
Description LSZH Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, LSZH bedding, single core AWA 2 or more cores SWA, LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 8x cable diameter
Core Identification 1 core Bn or Be
2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
5 core Gn/Yw, Be, Bn, Bk, Gy
Multicore - white cores with black printed numbers
Sheath Colour Black
Manufacturing Standard BS 6724
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Fire Tests N/A
Emissions and
Flame Propagation
LUL 1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Low Voltage 1.9/3.3kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description LSZH Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Solid aluminium conductors, XLPE insulation, cores laid up, LSZH bedding, single core AWA 2 or more cores SWA, LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 8 x overall diameter
Core Identification 1 core Bn or Be
2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
Sheath Colour Black
Manufacturing Standard BS 6724
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Low Voltage 1.9/3.3kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 1900/3300 volts
Description LSZH Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, LSZH bedding, single core AWA 2 or more cores SWA, LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 6x circular conductors
8x shaped conductors
Core Identification 1 core Bn or Be
3 core Bn, Bk, Gy
Sheath Colour Black
Manufacturing Standard BS 6724
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 12.7/22kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P27.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 12.7/22kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P27.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 12.7/22kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P13.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core 12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 12.7/22kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P13.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core 12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 19/33kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P28.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 19/33kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P28.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 19/33kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P14
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 19/33kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P14
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 3.8/6.6 kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P24.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 3.8/6.6 kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P24.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 3.8/6.6 kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P10.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 3.8/6.6 kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P10.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 6.35/11kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P25.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 6.35/11kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P25.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 6.35/11kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P11.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 6.35/11kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P11.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 8.7/15kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P26.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 8.7/15kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P26.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 8.7/15kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P12.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LSZH Medium Voltage 8.7/15kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description LSZH armoured power cables for use in fixed installations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment.
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P12.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS7835
Fire Tests N/A
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
LUL S1108 (formerly 1-108 & EME-SP-14-025) Track Feeder
LUL
Datasheet
Approval
Voltage Rating 750 volts
Description 500/630 and 935sqmm LFH track feeder cables. Now replaced by LUL Specification S1108 (formerly 1-108) and Metronet specification MR SE908. For use indoor or outdoor either as a power cable forming part of a DC traction supply within a substationand ending with connection to the traction conductor rail, or as a connector between two lengths of conductor rail. Can be laid unprotected over track ballast.
Construction Stranded tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 8 x diameter
Sheath Colour Black with yellow stripe
Manufacturing Standard 1-108 (EME-SP-14-025)
LV LSZH Auxilliary Power Cables
Datasheet
Voltage Rating 600/1000 volts
Description LSZH Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. For use in situations where smoke and acid gas emission from fire affected cables would be hazardous to people and equipment. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, LSZH bedding, SWA, LSZH sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 8x cable diameter
Core Identification White numbered cores
Sheath Colour Black
Manufacturing Standard BS 6724
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
LUL 1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
MPrint summary for selected product(s)
Print
Compare two selected products
Compare
MIC Heavy Duty (Bare)
SIRA
LPCB
Cert No 221h/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 750 volts
Description Mineral insulated cable delivers ultimate fire performance. It guarantees data transmission and security of power and control circuits by exceeding the requirements of BS8519-1 providing circuit integrity to 950C. It also exceeds enhanced grade requirements defined by BS 5839-1 26.2e and satisfies all Cat 1, 2 & 3 Power, and all Cat 1, 2 & 3 Control requirements defined by BS8519. It is the only true fire survival cable.
Construction Solid copper conductor. Compressed magnesium oxide powder insulation. Solid copper sheath.
Operating Temperature -10degC to +250degC
Minimum Bending Radius 6 x overall diameter
Core Identification Coloured sleeving available
Lengths Cables available in nominal lengths.
Sheath Colour N/A
Manufacturing Standard BS EN 60702-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 & power applications see special notes)
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
BS 8491
Emissions and
Flame Propagation
In its bare form there are no emissions
Special Notes 1 Testing at AEI confirms compliance with BS8519 Category 3 Control & Category 1, 2 & 3 Power ( clause II, note 2 for cables < 20mm OD)
2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
MIC Heavy Duty (LSZH)
LPCB
Cert No 221h/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 750 volts
Description Mineral insulated cable delivers ultimate fire performance. It guarantees data transmission and security of power and control circuits by exceeding the requirements of BS8519-1 providing circuit integrity to 950C. It also exceeds enhanced grade requirements defined by BS 5839-1 26.2e and satisfies all Cat 1, 2 & 3 Power, and all Cat 1, 2 & 3 Control requirements defined by BS8519. It is the only true fire survival cable.
Construction Solid copper conductor. Compressed magnesium oxide powder insulation. Solid copper sheath and thermoplastic LSZH sheath.
Operating Temperature -10degC to +250degC
Minimum Bending Radius 6 x overall diameter
Core Identification Coloured sleeving available
Lengths Cables available in nominal lengths.
Sheath Colour Red, White or Orange. Other colours available.
Manufacturing Standard BS EN 60702-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 & power applications see special notes)
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
BS 8491
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1 Testing at AEI confirms compliance with BS8519 Category 3 Control & Category 1, 2 & 3 Power ( clause II, note 2 for cables < 20mm OD)
2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
MIC Light Duty (Bare)
SIRA
LPCB
Cert No 221n/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 500 volts
Description Mineral insulated cable delivers ultimate fire performance. It guarantees data transmission and security of power and control circuits by exceeding the requirements of BS8519-1 providing circuit integrity to 950C. It also exceeds enhanced grade requirements defined by BS 5839-1 26.2e and satisfies all Cat 1, 2 & 3 Power, and all Cat 1, 2 & 3 Control requirements defined by BS8519. It is the only true fire survival cable.
Construction Solid copper conductor. Compressed magnesium oxide powder insulation. Solid copper sheath.
Operating Temperature -10degC to +250degC
Minimum Bending Radius 6 x overall diameter
Core Identification Coloured sleeving available
Lengths 100/500m. Special lengths available on request.
Sheath Colour N/A
Manufacturing Standard BS EN 60702-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 & power applications see special notes)
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
BS 8491
Emissions and
Flame Propagation
In its bare form there are no emissions
Special Notes 1 Testing at AEI confirms compliance with BS8519 Category 3 Control & Category 1, 2 & 3 Power ( clause II, note 2 for cables < 20mm OD)
2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
MIC Light Duty (LSZH)
LPCB
Cert No 221n/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 500 volts
Description Mineral insulated cable delivers ultimate fire performance. It guarantees data transmission and security of power and control circuits by exceeding the requirements of BS8519-1 providing circuit integrity to 950C. It also exceeds enhanced grade requirements defined by BS 5839-1 26.2e and satisfies all Cat 1, 2 & 3 Power, and all Cat 1, 2 & 3 Control requirements defined by BS8519. It is the only true fire survival cable.
Construction Solid copper conductor. Compressed magnesium oxide powder insulation. Solid copper sheath and thermoplastic LSZH sheath.
Operating Temperature -10degC to +250degC
Minimum Bending Radius 6 x overall diameter
Core Identification Coloured sleeving available
Lengths 100/500m
Special lengths available on request.
Sheath Colour Red, White or Orange. Other colours available.
Manufacturing Standard BS EN 60702-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 & power applications see special notes)
Fire Tests BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
BS 8491
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1 Testing at AEI confirms compliance with BS8519 Category 3 Control & Category 1, 2 & 3 Power ( clause II, note 2 for cables < 20mm OD)
2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
Mineral Insulated (EME-SP-14-028) Heavy Duty Bare
LPCB
Cert No 221h/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 750 volts
Description Mineral insulated cable delivers ultimate fire performance. It guarantees data transmission and security of power and control circuits by exceeding the requirements of BS8519-1 providing circuit integrity to 950C. It also exceeds enhanced grade requirements defined by BS 5839-1 26.2e and satisfies all Cat 1, 2 & 3 Power, and all Cat 1, 2 & 3 Control requirements defined by BS8519. It is the only true fire survival cable.
Construction Solid copper conductor. Compressed magnesium oxide powder insulation. Solid copper sheath.
Operating Temperature -10degC to +250degC
Minimum Bending Radius 6 x overall diameter
Core Identification Coloured sleeving available
Lengths Cables available in nominal lengths.
Sheath Colour N/A
Manufacturing Standard BS EN 60702-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 & power applications see special notes)
Fire Tests EME-SP-14-028-A1
BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
BS 8491
Emissions and
Flame Propagation
In its bare form there are no emissions
Special Notes 1 Testing at AEI confirms compliance with BS8519 Category 3 Control & Category 1, 2 & 3 Power ( clause II, note 2 for cables < 20mm OD)
2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
Mineral Insulated (EME-SP-14-028) Heavy Duty LSZH Sheath
LPCB
Cert No 221h/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 750 volts
Description Mineral insulated cable delivers ultimate fire performance. It guarantees data transmission and security of power and control circuits by exceeding the requirements of BS8519-1 providing circuit integrity to 950C. It also exceeds enhanced grade requirements defined by BS 5839-1 26.2e and satisfies all Cat 1, 2 & 3 Power, and all Cat 1, 2 & 3 Control requirements defined by BS8519. It is the only true fire survival cable.
Construction Solid copper conductor. Compressed magnesium oxide powder insulation. Solid copper sheath and thermoplastic LSZH sheath.
Operating Temperature -10degC to +250degC
Minimum Bending Radius 6 x overall diameter
Core Identification Coloured sleeving available
Lengths Cables available in nominal lengths.
Sheath Colour Red, White or Orange. Other colours available.
Manufacturing Standard BS EN 60702-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 & power applications see special notes)
Fire Tests EME-SP-14-028-A1+M13
BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
BS 8491
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1 Testing at AEI confirms compliance with BS8519 Category 3 Control & Category 1, 2 & 3 Power ( clause II, note 2 for cables < 20mm OD)
2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
Mineral Insulated (EME-SP-14-028) Light Duty Bare
LPCB
Cert No 221n/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 500 volts
Description Mineral insulated cable delivers ultimate fire performance. It guarantees data transmission and security of power and control circuits by exceeding the requirements of BS8519-1 providing circuit integrity to 950C. It also exceeds enhanced grade requirements defined by BS 5839-1 26.2e and satisfies all Cat 1, 2 & 3 Power, and all Cat 1, 2 & 3 Control requirements defined by BS8519. It is the only true fire survival cable.
Construction Solid copper conductor. Compressed magnesium oxide powder insulation. Solid copper sheath.
Operating Temperature -10degC to +250degC
Minimum Bending Radius 6 x overall diameter
Core Identification Coloured sleeving available
Lengths 100/500m
Special lengths available on request.
Sheath Colour N/A
Manufacturing Standard BS EN 60702-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 & power applications see special notes)
Fire Tests EME-SP-14-028-A1
BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
BS 8491
Emissions and
Flame Propagation
In its bare form there are no emissions
Special Notes 1 Testing at AEI confirms compliance with BS8519 Category 3 Control & Category 1, 2 & 3 Power ( clause II, note 2 for cables < 20mm OD)
2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
Mineral Insulated (EME-SP-14-028) Light Duty LSZH Sheath
LPCB
Cert No 221n/01
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 500 volts
Description Mineral insulated cable delivers ultimate fire performance. It guarantees data transmission and security of power and control circuits by exceeding the requirements of BS8519-1 providing circuit integrity to 950C. It also exceeds enhanced grade requirements defined by BS 5839-1 26.2e and satisfies all Cat 1, 2 & 3 Power, and all Cat 1, 2 & 3 Control requirements defined by BS8519. It is the only true fire survival cable.
Construction Solid copper conductor. Compressed magnesium oxide powder insulation. Solid copper sheath and thermoplastic LSZH sheath.
Operating Temperature -10degC to +250degC
Minimum Bending Radius 6 x overall diameter
Core Identification Coloured sleeving available
Lengths 100/500m
Special lengths available on request.
Sheath Colour Red, White or Orange. Other colours available.
Manufacturing Standard BS EN 60702-1
Code of Practice/
Guide to Use
BS 5839-1 Clause 26.2e Enhanced
BS 5266
BS 8519 Category 1 & 2 Control
(for Category 3 & power applications see special notes)
Fire Tests EME-SP-14-028-A1
BS 8434-2
BS EN 50200 PH30, PH60, PH120
BS 6387 C W & Z
BS 8491
Emissions and
Flame Propagation
1-085
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes 1 Testing at AEI confirms compliance with BS8519 Category 3 Control & Category 1, 2 & 3 Power ( clause II, note 2 for cables < 20mm OD) 2 Methods of cable support should withstand a similar temperature and duration to that of the cable.
NPrint summary for selected product(s)
Print
Compare two selected products
Compare
NCB 115 Shotfiring Cables
Datasheet
3D Model
Description Shotfiring cables for use other than in shafts
Construction Type 1 Twin parralel cores, stranded plain copper conductors, PVC insulated
Type 2 Single core, stranded plain copper conductors, PVC insulated, PVC sheathed
Operating Temperature -10degC to +70degC
Minimum Bending Radius 6x cable diameter.
Core Identification White
Sheath Colour White
Manufacturing Standard NCB 115 Shotfiring Cables
NCB 492 Telephone Cables
Datasheet
3D Model
Voltage Rating 110 volts
Description Multipair armoured telephone cables providing communications between all areas underground and with the surface.
Construction Plain copper conductors, PVC insulated pairs, pairs laid up, PVC bedding, single or double galvanised steel wire armour, PVC sheath.
Operating Temperature -10degC to +70degC
Minimum Bending Radius 6x cable diameter.
Core Identification As NCB 492 table 4
Sheath Colour Black
Manufacturing Standard NCB 492 Telephone Cables
NR/L2/ELP/40045 Point Heater Cables
Datasheet
Voltage Rating 300/500 volts
Description Cables fo use on electric point heating installations
Construction Flexible tinned copper, EPR insulation, heavy duty sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 8 x diameter
Core Identification 4 core Yw, Yw, Be, Be
8 core Yw, Yw, Be, Be, Bn, Bn, Bk, Bk
Sheath Colour Black
Manufacturing Standard NR/L2/ELP/40045
Emissions and
Flame Propagation
IEC60332
NR/PS/ELP/21101 (DC112) Track Feeder
Datasheet
Approval
Voltage Rating 750 volts
Description Traction cables for use on dc traction systems to provide the supply from traction substations and track paralleling huts to the conductor rails and negative cable connections and, where appropriate, bonding.
Construction Stranded tinned copper or aluminium conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 8 x diameter for copper
10x for aluminium
Sheath Colour Black
Manufacturing Standard NR/PS/ELP/21101
NR/PS/SIG/00005 (formerly RT/E/PS/00005) Type A1&A3
Datasheet
Approval
Voltage Rating 650/1100 volts
Description Singlcore A1 and multicore A3 cables for light duty applications, often in ducting.
Construction A1 - Stranded tinned copper conductors, LSZH insulation
A3 - Stranded tinned copper conductors, LSZH insulation, LSZH sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard NR/PS/SIG/00005 Type A1&A3
Fire Tests N/A
Emissions and
Flame Propagation
BS 4066-1
NR/PS/SIG/00005 (formerly RT/E/PS/00005) Type B1-B2
Datasheet
Approval
Voltage Rating 650/1100 volts
Description Singlecore B1, twin and multicore B2 cables
Construction B1 - singlecore, stranded tinned copper conductors, EPR insulation, heavy duty sheath
B2 - twin and multicore, stranded tinned copper conductors, EPR insulation, heavty duty sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard NR/PS/SIG/00005 Type B1&B2
Fire Tests N/A
Emissions and
Flame Propagation
BS 4066-1
NR/PS/SIG/00005 (formerly RT/E/PS/00005) Type C2
Datasheet
Approval
Voltage Rating 650/1100 volts
Description Flexible twin and multicore cables suitable for tails.
Construction Twin and multicore cables, flexible conductors, EPR insulation, heavy duty sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard NR/PS/SIG/00005 Type C2
Fire Tests N/A
Emissions and
Flame Propagation
BS 4066-1
NR/PS/SIG/00005 (formerly RT/E/PS/00005) Type C3
Datasheet
Approval
Voltage Rating 650/1100 volts
Description Flexible twisted pair, screened cable, for use on train protection warning systems (TPWS).
Construction Single pair with flexible conductors, EPR insulated, laid up with a drain wire in contact with an aluminium/PETP taped screen, heavy duty sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard NR/PS/SIG/00005 Type C3
Fire Tests N/A
Emissions and
Flame Propagation
BS 4066-1
NR/PS/SIG/00005 (formerly RT/E/PS/00005) Type D2
Datasheet
Approval
Voltage Rating 650/1100 volts
Description Twin and multicore cables.
Construction Twin and multicore cables, stranded tinned copper conductors, EPR insulation, heavty duty sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard NR/PS/SIG/00005 Type D2
Fire Tests N/A
Emissions and
Flame Propagation
BS 4066-1
NR/PS/SIG/00005 (formerly RT/E/PS/00005) Type E2
Datasheet
Approval
Voltage Rating 650/1100 volts
Description Flexible twin and multicore LSZH cables suitable for tails.
Construction Twin and multicore cables, flexible conductors, EPR insulation, heavy duty LSZH sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard NR/PS/SIG/00005 Type E2
Fire Tests N/A
Emissions and
Flame Propagation
BS 4066-1
NR/PS/SIG/00005 (formerly RT/E/PS/00005) Type E3
Datasheet
Approval
Voltage Rating 650/1100 volts
Description Flexible twisted pair, screened LSZH cable, for use on train protection warning systems (TPWS).
Construction Single pair with flexible conductors, LSZH insulated, laid up with a drain wire in contact with an aluminium/PETP taped screen, heavy duty LSZH sheath
Operating Temperature -25degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard NR/PS/SIG/00005 Type E3
Fire Tests N/A
Emissions and
Flame Propagation
BS 4066-1
PPrint summary for selected product(s)
Print
Compare two selected products
Compare
PVC Low Voltage 0.6/1.0kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description PVC Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Solid aluminium conductors, XLPE insulation, cores laid up, PVC bedding, single core AWA 2 or more cores SWA, PVC sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 8x overall diameter
Core Identification 1 core Bn or Be
2 core Bn, Be
3 core Bn, Bk, Gy
4 core Bn, Bk, Gy, Be
Sheath Colour Black
Manufacturing Standard BS 5467
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Low Voltage 0.6/1.0kV Copper
BASEC
 Product Image
Datasheet
Approval  
3D Model
Voltage Rating 600/1000 volts
Description PVC Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, PVC bedding, single core AWA 2 or more cores SWA, PVC sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 6x circular conductors
8x shaped conductors
Core Identification 1 core Bn or Be
2 core Bn, Be
3 core Bn, Bk,Gy
4 core Bn, Bk, Gy, Be
5 core Gn/Yw, Be, Bn, Bk, Gy
Multicore - white cores with black printed numbers
Sheath Colour Black
Manufacturing Standard BS 5467
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Low Voltage 1.9/3.3kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 1900/3300 volts
Description PVC Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Solid aluminium conductors, XLPE insulation, cores laid up, PVC bedding, single core AWA 2 or more cores SWA, PVC sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 8 x overall diameter
Core Identification 1 core - Bn or Be
3 core - Bn, Bk, Gy
Sheath Colour Black
Manufacturing Standard BS 5467
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Low Voltage 1.9/3.3kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 1900/3300 volts
Description PVC Armoured cables for use in fixed installations in industrial areas, buildings and similar applications. They may be installed in air, on trays, clipped direct or be buried in the ground.
Construction Stranded plain copper conductors, XLPE insulation, cores laid up, PVC bedding, single core AWA 2 or more cores SWA, PVC sheath.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 6x circular conductors
8x shaped conductors
Core Identification 1 core Bn or Be
3 core Bn, Bk, Gy
Sheath Colour Black
Manufacturing Standard BS 5467
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 12.7/22kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P22.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 12.7/22kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P22.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 12.7/22kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P8.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 12.7/22kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 12700/22000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P8.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 19/33kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P23.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 19/33kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P23.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 19/33kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P9.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 19/33kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 19000/33000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P9.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 3.8/6.6 kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P19.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 3.8/6.6 kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded aluminium conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P19.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 3.8/6.6 kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P5.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 3.8/6.6 kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 3800/6600 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P5.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 6.35/11kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P20.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 6.35/11kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P20.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 6.35/11kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P6.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 6.35/11kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 6350/11000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P6.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 8.7/15kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P21.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 8.7/15kV Aluminium
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P21.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 8.7/15kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P7.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
PVC Medium Voltage 8.7/15kV Copper
 Product Image
Datasheet
3D Model
Voltage Rating 8700/15000 volts
Description PVC armoured power cables for use in fixed installations
Construction Core construction - Stranded plain copper conductors, SC conductor screen, XLPE insulation, SC insulation screen, plain copper tape. For optional cable constructions refer Technical Data Sheet P7.
Operating Temperature -15degC to +90degC
Minimum Bending Radius 15x for single core
12x for 3 core
Core Identification 3 core Rd, Yw, Be or by numbers
Sheath Colour Black or Red
Manufacturing Standard BS6622
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 60332
Special Notes Minimum temperature for installation purposes is 0degC
Protec
BASEC
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 300/500 volts
Description Screened cable for use in walls, partitions and building voids where there is a risk of damage or penetration from nails, screw fixings etc.
Construction Solid or stranded plain copper conductors, XLPE insulation, full size earth, aluminium tubed screen, LSZH sheath.
Operating Temperature -25degC to +90degC
Minimum Bending Radius 6 x overall diameter
Core Identification 2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
Lengths 100m
Sheath Colour White, other colours available
Manufacturing Standard BS8436
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC.
Once installed and fixed can operate to -25degC
Protec Power
BASEC
 Product Image
Datasheet
Approval
3D Model
Voltage Rating 600/1000 volts
Description A lightweight, robust, screened cable for use in power applications that require a moderate level of mechanical protection and a cleaner power supply for EMC purposes.
Construction Stranded plain copper conductors, XLPE insulation, full size earth, aluminium tubed screen, LSZH sheath.
Operating Temperature -25degC to +90 degC
Minimum Bending Radius 6 x overall diameter
Core Identification 2 core Bn, Be
3 core Bn, Blk, Gy
4 core Bn, Blk, Gy, Be
Lengths 100m
Sheath Colour Black, other colours available
Manufacturing Standard IS273
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265,50266 (IEC 60332) Flame Propagation
Special Notes Minimum temperature for installation purposes is 0degC
. Once installed and fixed can operate to -25degC
RPrint summary for selected product(s)
Print
Compare two selected products
Compare
RIA10 Jumper Cables
Datasheet
Voltage Rating 300/500
600/1000 volts
Description Twin, milticore and multipair flexible control jumper cables for use between and within railway vehicles.
Construction Flexible tinned copper conductors, LFH insulation, LFH sheath
Operating Temperature -30C to +85C
Minimum Bending Radius 5x cable diameter fixed
8x cable diameter flexing
Core Identification 2 core BN & BE
mulicores and multipairs numbered
Sheath Colour Black
Manufacturing Standard RIA10
RIA21 (RIA7,11)
Datasheet
3D Model
Voltage Rating 300/500
600/1000
1900/3300 volts
Description Singlecore cables for use in protected or exposed installations on traction and rolling stock
Construction Flexible tinned copper conductors, LFH insulation, LFH sheath
Operating Temperature -30C to +85C
Minimum Bending Radius 5x cable diameter fixed
8x cable diameter flexing
Sheath Colour Black
Manufacturing Standard RIA21
RSE/STD/024 Pt 6 Type I
LUL
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description Reduced wall single core cable for use in rolling stock.
Construction Stranded tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Red
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type I
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type II
LUL
Datasheet
Voltage Rating 600/1000 volts
Description Standard wall single core cable for use in rolling stock.
Construction Flexible tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Red
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type II
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type III
LUL
Datasheet
Voltage Rating 600/1000 volts
Description Enhanced wall single core cable for use in rolling stock.
Construction Flexible tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Red
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type III
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type IV
LUL
Datasheet
3D Model
Voltage Rating 30/50 volts
Description Reduced wall single core cable for use in rolling stock.
Construction Stranded tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Normally violet
yellow for safety circuits
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type IV
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type IX
LUL
Datasheet
Voltage Rating 30/50 volts
Description Reduced wall pair and multipair cable with standard sheath for use in rolling stock.
Construction Type IV cores (stranded tinned copper conductors, LFH insulation), cores twinned, individually screened with tinned copper drain wire, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Blue and brown
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard RSE/STD/024 Pt 6 Type IX
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type V
LUL
Datasheet
3D Model
Voltage Rating 30/50 volts
Description Standard wall single core cable for use in rolling stock.
Construction Stranded tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Normally violet
yellow for safety circuits
Lengths Cut lengths on request.
Sheath Colour N/A
Manufacturing Standard RSE/STD/024 Pt 6 Type V
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type VI
LUL
Datasheet
Voltage Rating 600/1000 volts
Description Standard wall multicore cable with enhanced sheath for use in rolling stock.
Construction Type II cores (flexible tinned copper conductors, LFH insulation), cores layed up, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 3x D if D is <10mm dia
4x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Red
Lengths Cut lengths on request.
Sheath Colour Black with yellow stripe
Manufacturing Standard RSE/STD/024 Pt 6 Type VI
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type VII
LUL
Datasheet
Voltage Rating 30/50 volts
Description Standard wall multicore cable with enhanced sheath for use in rolling stock.
Construction Type V cores (flexible tinned copper conductors, LFH insulation), cores layed up, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 3x D if D is <10mm dia
4x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Normally violet
yellow for safety circuits
Lengths Cut lengths on request.
Sheath Colour Black with yellow stripe
Manufacturing Standard RSE/STD/024 Pt 6 Type VII
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type VIII
LUL
Datasheet
Voltage Rating 30/50 volts
Description Standard wall pair and multipair cable with standard or enhanced sheath for use in rolling stock.
Construction Type V cores (flexible tinned copper conductors, LFH insulation), cores twinned, individually screened with tinned copper drain wire, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Blue and brown
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard RSE/STD/024 Pt 6 Type VIII
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type XI
LUL
Datasheet
Voltage Rating 600/1000 volts
Description Reduced wall pair and multipair cable with standard sheath for use in rolling stock.
Construction Type I cores (stranded tinned copper conductors, LFH insulation), cores twinned, individually screened with tinned copper drain wire, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 6x cable diameter
Core Identification Red and white
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard RSE/STD/024 Pt 6 Type XI
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type XII
LUL
Datasheet
3D Model
Voltage Rating 300/500 volts
Description Standard wall single core cable for use in rolling stock.
Construction Flexible tinned copper conductors, LFH insulation.
Operating Temperature -30degC to +85degC
Minimum Bending Radius 2x D if D is <10mm dia
3x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Green
Lengths Cut lengths on request.
Sheath Colour Black
Manufacturing Standard RSE/STD/024 Pt 6 Type XII
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
RSE/STD/024 Pt 6 Type XIII
LUL
Datasheet
Voltage Rating 300/500 volts
Description Standard wall multicore cable with enhanced sheath for use in rolling stock.
Construction Type XII cores (flexible tinned copper conductors, LFH insulation), cores layed up, LFH sheath
Operating Temperature -30degC to +85degC
Minimum Bending Radius 3x D if D is <10mm dia
4x D if D is 10mm to 25mm
6x D if D is >25mm dia
Core Identification Green
Lengths Cut lengths on request.
Sheath Colour B+K12lack with yellow stripe
Manufacturing Standard RSE/STD/024 Pt 6 Type XIII
Code of Practice/
Guide to Use
S1121
Fire Tests N/A
Emissions and
Flame Propagation
1-085 Flame Propagation
1-085 Smoke Emission
1-085 Toxicity
SPrint summary for selected product(s)
Print
Compare two selected products
Compare
SE1047 Types 1&3
LUL
Datasheet
Voltage Rating 600/1000 volts
Description PVC railway signalling cable for use in trackside bracket runs
Construction Solid wire tinned copper conductor, PVC insulated, spiral wound concentric conductor, PVC insulated, tinned copper wire screen (type 3 only), 1, 3, 7, 19 pairs laid up, PVC sheathed
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black with numbers
Sheath Colour Red
Manufacturing Standard SE1047
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE1047 Types 2&4
LUL
Datasheet
Voltage Rating 600/1000 volts
Description LSC railway signalling cables for use in trackside bracket runs
Construction Solid wire tinned copper conductor, LSZH insulated, spiral wound concentric conductor, LSZH insulated, tinned copper wire screen (type 4 only), 1, 3, 7, 19 pairs laid up, LSZH sheathed
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black with numbers
Sheath Colour Red
Manufacturing Standard SE1047
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE1093
Datasheet
Voltage Rating 600/1000 volts
Description Single core cable for use as replacement wire in railway signalling applications in trackside cases, enclosures and equipment rooms.
Construction Stranded tinned copper wire, EPR insulated, LFH sheathed
Operating Temperature -15C to +90C
Minimum Bending Radius 2x cable diameter
Core Identification White
Sheath Colour 0.5sqmm Violet
1.0sqmm Red
Manufacturing Standard MR-SE-1093
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
2-01001-002
SE260
Datasheet
Voltage Rating 1000 volts
Description Pigtail rail connection for underground and surface locations
Construction 16sqmm stranded plain or tinned copper wires, PVC or LSZH insulation, PVC or LSZH sheath.
Operating Temperature -25degC to +85degC
Minimum Bending Radius 3 x diameter
Core Identification white, others on request
Sheath Colour PVC grey
LSZH red or black
Manufacturing Standard SSL-SE-0260
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085 LSZH only
SE330
Datasheet
Voltage Rating 600/1000 volts
Description 10 core screened Track Crossing Signalling Cable for connection to track mounted signals, points and trainstops.
Construction 10 core solid wire tinned copper conductor, EPR insulated, tinned copper screen, LFH sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Numbered
Sheath Colour Black
Manufacturing Standard SSL-SE-0330
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE527
Datasheet
Voltage Rating 250 volts
Description Screened signalling circuits for use in crossing tracks
Construction Central single solid tinned conductor, EPR insulated, concentric spiral wound conductor, EPR insulation, tinned copper screen, 3 core or 5 core with telephone wires laid up and sheathed.
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification 3 core Rd, We, Bk
5 core Rd, We, Bk, Be, Gn
Sheath Colour Black
Manufacturing Standard SSL SE-0527
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE64
Description Tunnel Telephone Wire
Construction Tinned phosphor bronze wire
Manufacturing Standard SE64
Code of Practice/
Guide to Use
E4156 Part 1
S1121
SE774
Datasheet
Voltage Rating 700 volts
Description Singlecore cables for equipment room signalling power supplies and earthing
Construction Stranded tinned copper conductors, LFH insulation
Operating Temperature -15C to +85C
Minimum Bending Radius 1 to 16sqmm 2 x cable diameter
35sqmm 3 x cable diameter
Core Identification N/A
Sheath Colour Bk, Yw or Gn/Yw
Manufacturing Standard SSL-SE-0774
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE774
Datasheet
Voltage Rating 700 volts
Description Singlecore cables for equipment room signalling power supplies and earthing
Construction Stranded tinned copper conductors, LFH insulation
Operating Temperature -15C to +85C
Minimum Bending Radius 1 to 16sqmm 2 x cable diameter
35sqmm 3 x cable diameter
Core Identification N/A
Sheath Colour Bk, Yw or Gn/Yw
Manufacturing Standard SSL-SE-0774
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE882
Datasheet
Voltage Rating 1000 volts
Description 2 core AC signal main cable providing power from sub-stations to signalling equipment
Construction Stranded tinned copper conductors, 35sqmm or 70sqmm, thermoplastic LSZH insulation, thermoplastic LSZH sheath
Operating Temperature -15C to +90C
Minimum Bending Radius 6x cable diameter
Core Identification Bn/Be
Sheath Colour Yellow
Manufacturing Standard MR-SE-882
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE895
LUL
Datasheet
Voltage Rating 120 volts
Description LSZH track circuit feed cable
Construction 4sqmm stranded tinned copper wire, LSZH insulation, LSZH sheath.
Operating Temperature -15C to +85C
Minimum Bending Radius 2x cable diameter
Core Identification Black
Sheath Colour Black
Manufacturing Standard SE895
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
SE966
Voltage Rating 120 volts
Description Multipair screened cable for use with data transmission systems. Suitable for use in equipment rooms, tunnels and frieze runs behind station platform walls
Construction Stranded tinned copper conductors, PE insulation, screen, sheath
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification 1 pair Bk/We
3 pair Bk/We, Bk/Rd, Bk/Gn
5 pair Bk/We, Bk/Rd, Bk/Gn, Bk/Be, Bk/Yw
Sheath Colour Grey
Manufacturing Standard SE966
Code of Practice/
Guide to Use
E4156 Part 1
S1121
TPrint summary for selected product(s)
Print
Compare two selected products
Compare
T0504 (formerly SE902)
Datasheet
Voltage Rating 3000 volts
Description Singlecore cables for use in d.c. traction indication circuits and rail connection circuits
Construction Stranded tinned copper conductors, LFH insulation
Operating Temperature -15C to +85C
Minimum Bending Radius 6x cable diameter
Core Identification Black
Sheath Colour Black or black with yellow stripe
Manufacturing Standard T0504 (formerly SE902)
Code of Practice/
Guide to Use
E4156 Part 1
S1121
Emissions and
Flame Propagation
1-085
TC104 (TM104)
Datasheet
3D Model
Voltage Rating 250 and 600 volts
Description Halogen free thin wall cables for rail and rolling stock
Construction Stranded tinned copper wire, thin wall LSZH insulation, single or multicore, optional screen, LSZH sheath
Operating Temperature -40degC to +105degC
Minimum Bending Radius 3x for single core unscreened
8x for screened
Core Identification As required
Sheath Colour As required
Manufacturing Standard TC1-04
Emissions and
Flame Propagation
BS 6853 1a, 1b, 11
NFF 16 101 FO
TC105 (TM105)
Datasheet
3D Model
Voltage Rating 500
1000
3000 volts
Description Standard wall rolling stock cables for use in TMST and SNCF rolling stock
Construction Stranded tinned copper wire, standard wall LSZH insulation, single or multicore, LSZH sheath
Operating Temperature -25degC to +105degC
Minimum Bending Radius <10mm 3x
>10mm 4x for static
>10mm 5x for flexing
Core Identification As required
Sheath Colour As required
Manufacturing Standard TC1-05
Emissions and
Flame Propagation
BS 6853 1a, 1b, 11
NFF 16 101 FO
TC12
Datasheet
3D Model
Voltage Rating 600/1000
1800/3000
3600/6000 volts
Description Standard wall rolling stock cables for use in general purpose applications covered by the EN and similar, includes single and multi core cables. Bespoke designs can be supplied
Construction Singlecore flexible tinned copper conductors, LFH insulation
Operating Temperature -25degC to +105degC
Minimum Bending Radius <10mm 3x
>10mm 4x for static
>10mm 5x for flexing
Core Identification Black
Sheath Colour N/A
Manufacturing Standard TC12
Meets requirements of EN50264-2-1
Emissions and
Flame Propagation
BS 6853 1a, 1b, 11
NFF 16 101 FO
Table 10: FEPDS
Datasheet
Voltage Rating 500
750 volts
Description Flexible cables for field electrical power distribution and connections to and between mobile equipment.
Construction Single, 3 and 5 core with or without pilot, flexible tinned copper conductors, EPR insulation, cores laid up, CSP sheath
Operating Temperature -34degC to +85degC
Minimum Bending Radius 10x overall diameter
Core Identification 1 core bk
3 core bn, be gn/yw
5 core bn, be, bk, gy, gn/yw
optional pilot core to be white
Lengths To order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 27 Table 10
Table 11: Multicore (Collective Screen) 0.20mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 11
Table 12: Multicore (Collective Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 12
Table 13: Multicore (Collective Screen) 0.60mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 13
Table 14, 26: Multicore (Collective Screen) 1.00mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 14 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 26 (Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 14, 26
Table 15: Multipair (Collective Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multipair collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 15
Table 16: Multipair (Collective Screen) 1.00mm²
Datasheet
Voltage Rating 600 volts
Description Multipair collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 16
Table 17: Multipair (Individual Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multipair individually screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 17
Table 18: Multipair (Individual Screen) 1.00mm²
Datasheet
Voltage Rating 600 volts
Description Multipair individually screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 18
Table 19: Multipair (Individual/Collective Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multipair individually and collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs screened with TCWB, layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered pairs.
1st pair rd/bk, 2nd pair be/bk, all other pairs we/bk
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 19
Table 20: Multitriple (Collective Screen) 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multitriple collectively screened LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multitriple cables, stranded tinned copper conductor, LFH insulated Part 18 cores, pairs layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Numbered triples.
Each triple rd/we/be
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 20
Table 27: Multicore (Collective Screen) 1.50mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in power applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Be, bn gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 27
Table 28: Multicore (Collective Screen) 2.50mm²
Datasheet
Voltage Rating 600 volts
Description Multicore collectively screened LFH cables suitable for use in power applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core bn, be
3 core bn, be, gn/yw
4 core bn, be, bk, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 28
Table 4: Multicore 0.20mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 4
Table 5: Multicore 0.35mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification 2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 5
Table 6, 22: Multicore 0.60mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 6 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 22 (Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 6, 22
Table 7, 21, 23: Multicore 1.00mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 7 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 21 (Power)
2 core be, bn

Table 23(Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 7, 21, 23
Table 8, 24: Multicore 1.50mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 8 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 24 (Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 8, 24
Table 9, 25: Multicore 2.50mm²
Datasheet
Voltage Rating 600 volts
Description Multicore LFH cables suitable for use in power and communications applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, LFH insulated Part 18 cores, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 4x overall diameter fixed
10x overall diameter flexing
Core Identification Table 9 (Control)
2 core rd, be
3 core rd, be, we
4+ cores numbered rd, be marker cores remainder white in each layer

Table 25 (Power)
3 core be, bn, gn/yw
Lengths 100/500m or to order
Sheath Colour Black
Manufacturing Standard Def Stan 61-12 Part 25 Table 9, 25
Table B10: Multicore (Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Screened flexible instrumentation cables for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Stranded and flexible tinned copper conductors, LFH insulation, cores individualy screened, cores laid up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification 521-8530 Bn, Yw, Be, Gn
521-8531 Bn, Yw, Be, Gn
others numbered
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-526 Table B10
Fire Tests N/A
Special Notes 521-8530 is rated at 750V
521-8531 is rated at 1100V
Table B1: Single core
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Single core cables for use in power and lighting circuits where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Single core, stranded tinned copper conductors, LFH insulation, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification Bk
Lengths 250/ 500m
Sheath Colour N/A
Manufacturing Standard Def Stan 02-526 Table B1
Fire Tests N/A
Table B2: Single core (Flexible)
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Flexible single core cables for use in power and lighting circuits where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Single core, flexible tinned copper conductors, LFH insulation, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification Bk
Lengths 250/ 500m
Sheath Colour N/A
Manufacturing Standard Def Stan 02-526 Table B2
Fire Tests N/A
Table B4: Single & Multicore (Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Screened instrumentation cables for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Flexible tinned copper conductors, LFH insulation, cores laid up, LFH sheath, TCWB.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification 1 core Be
2 core Bn, Be
3 core Bn, Be, Gn/Yw
4 core Bn, Yw, Be, Gn
5 core Bn, Yw, Be, Gn, Bk
Multicores - numbered
Lengths 100/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-526 Table B4
Fire Tests N/A
Table B5: Multicore
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Multicore cables for use in power and lighting circuits where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Stranded tinned copper conductors, LFH Insulation, cores laid up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification Bk
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-526 Table B5
Fire Tests N/A
Table B6: Multicore (Degaussing)
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Degausing cables for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Stranded tinned copper conductors, LFH Insulation, cores laid up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification Bk
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-526 Table B6
Fire Tests N/A
Table B7: Multicore (Special Flexing)
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Special flexing cables for use in power, lighting and control circuits for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Flexible tinned copper conductors, LFH Insulation, cores laid up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification Bk
Lengths 100/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-526 Table B7
Fire Tests N/A
Table B8: Multicore (Special Flexing & Screen)
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Screened special flexing cables for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Flexible tinned copper conductors, LFH Insulation, cores laid up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification Bk
Lengths 500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-526 Table B8
Fire Tests N/A
Table B9: Multicore (Individual Screen)
Datasheet
Voltage Rating 440 volts
Description Rubber insulated Low Fire Hazard (LFH) sheathed cables. Screened flexible instrumentation cables for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Stranded tinned copper conductors, LFH insulation,TCW/nylon braid, cores laid up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification Bk
Lengths 500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-526 Table B9
Fire Tests N/A
Table C10: Miniature Multipair/triple (Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Miniature multipair and multitriple fire resistant cables, collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Miniature multipair and multitriple cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, pairs/triples layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 100m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C10
Fire Tests BS6387
Table C11: Miniature Multicore (Individual and Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Miniature multicore fire resistant cables, individually and collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Miniature multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, TCWB, cores layed up TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 100/250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C11
Fire Tests BS6387
Table C1: Single core
Datasheet
Voltage Rating 440 volts
Description Singlecore, fire resistant cables with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Singlecore stranded tinned copper conductor, silicone insulated, glass fibre braided (Type E) or silicone impregnated glass tape (Type T) insulation, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C1
Fire Tests BS6387
Table C2: Two & Three core
Datasheet
Voltage Rating 440 volts
Description Twin and three core, fire resistant cables with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Twin and three core cables, stranded tinned copper conductor, silicone insulated, glass fibre braided (Type E) or silicone impregnated glass tape (Type T) insulation, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C2
Fire Tests BS6387
Table C3: Multicore
Datasheet
Voltage Rating 440 volts
Description Multicore, fire resistant cables with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided (Type E) or silicone impregnated glass tape (Type T) insulation, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C3
Fire Tests BS6387
Table C4: Twin & Multicore
Datasheet
3D Model
Voltage Rating 440 volts
Description Multicore, fire resistant control cables with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250/500m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C4
Fire Tests BS6387
Table C5: Multipair (Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Multipair, fire resistant cables, collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, cores twinned and layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C5
Fire Tests BS6387
Table C6: Multicore (Individual Screen)
Datasheet
Voltage Rating 440 volts
Description Multicore fire resistant cables, individually screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, TCWB, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C6
Fire Tests BS6387
Table C7: Multipair (Individual Screen)
Datasheet
Voltage Rating 440 volts
Description Multipair fire resistant cables, individually screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multipair cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, TCWB, cores layed up, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C7
Fire Tests BS6387
Table C8: Multicore (Collective Screen)
Datasheet
Voltage Rating 440 volts
Description Multicore fire resistant cables, collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, cores layed up, TCWB, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 250m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C8
Fire Tests BS6387
Table C9: Miniature Multicore
Datasheet
Voltage Rating 440 volts
Description Miniature multicore fire resistant cables, unscreened or individually or collectively screened, with Low Fire Hazard (LFH) sheaths for use in applications where fuel and lubricating oils, hydraulic fluids and water are present.
Construction Miniature multicore cables, stranded tinned copper conductor, silicone insulated, glass fibre braided, unscreened or individually or collectively screened, LFH sheath.
Operating Temperature -30degC to +105degC
Minimum Bending Radius 6x overall diameter
Core Identification White with numbers
Lengths 100m
Sheath Colour Black
Manufacturing Standard Def Stan 02-527 Table C9
Fire Tests BS6387
Tri-Rated
 Product Image
Datasheet
3D Model
Voltage Rating 600/1000 volts
Description Tri rated panel wiring
Construction Flexible plain copper conductoor, HRPVC insulation
Operating Temperature +5degC to +90degC
Minimum Bending Radius 3x for fixed cable
6x for flexing.
Core Identification Bk, We, Rd, Bn, Be, Yw, Gn/Yw, Gy.
Lengths 100m
Sheath Colour N/A
Manufacturing Standard BS6231 Type CK Table 2.
UL758
CSA C22.2 No 127-95
Fire Tests N/A
Emissions and
Flame Propagation
BS 4066-1
CSA C22.2 FT1
UL 1581 VW1
Special Notes Cables 150sqmm and above are bi-rated.
VPrint summary for selected product(s)
Print
Compare two selected products
Compare
VDE E PV 01
Datasheet
Voltage Rating 1.1/1.8dc volts
Description Solar Cables - DI double insulated. Suitable for use indoor or outdoor for connection between solar panels or between panels and invertor.
Construction Flexible tinned copper conductor, LSZH insulated, LSZH sheathed.
Operating Temperature -40degC to +105degC
20000 hours @120degC
Minimum Bending Radius Refer data sheet
Core Identification 1 core Black
Lengths 100, 500
Sheath Colour Black
Manufacturing Standard VDE E PV 01
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emission
BS EN 50265, EN50266(IEC 60332) Flame Propagation
VDE E PV 01
Datasheet
Voltage Rating 1.1/1.8dc volts
Description Solar Cables - IS insulated and sheathed. Suitable for use indoor or outdoor for connection between solar panels or between panels and invertor.
Construction Flexible tinned copper conductor, LSZH insulated, LSZH sheathed.
Operating Temperature -40degC to +105degC
20000 hours @120degC
Minimum Bending Radius Refer data sheet
Core Identification 1 core Black
Lengths 100, 500
Sheath Colour Black
Manufacturing Standard VDE E PV 01
Fire Tests N/A
Emissions and
Flame Propagation
BS EN 50267 (IEC 60754) Acid Gas Emission
BS EN 50268 (IEC 61034) Smoke Emissio
BS EN 50265, EN50266(IEC 60332) Flame Propagation

product

Product Categories

Current Ratings

Navigation Key

  • Product Datasheet
  • Product Approval(s)
  • Product 3D Model
  • Compare two selected products
  • Print summary data for selected products

Helpful Hints

  • info

    Product detail can be viewed by clicking on the desired product title.

  • info

    When viewing a 3D cable model, use the mouse to control rotation. The names of component parts will be shown when hovering over the model.